FM-01: The Saw Is Completely Dead - No Worklight And No Motor Response
A charged-looking battery is installed and the trigger is pulled, but the worklight never comes on and the blade does not move.
Diagnostic overview
A charged-looking battery is installed and the trigger is pulled, but the worklight never comes on and the blade does not move.
Likely Root Causes
- FLEXVOLT battery is discharged, protected, damaged, or not fully seated
- Battery rails or accessible contacts are dirty, wet, burned, or damaged
- Trigger lock-off is not being released
- Trigger switch, electronic module, motor, or internal power path has failed
Quick Checks
- With a proven pack installed, the worklight responds to trigger operation and the blade reaches normal no-load speed.
Repair Preview
- Set the saw on its side with the trigger released, remove the battery, and keep the blade clear of people and material.
- - Inspect the pack, rails, latch, and accessible contacts for cracks, swelling, liquid, scorching, unusual heat, or debris - route any battery hazard to FM-06
- Charge the pack with its designated charger, clean only dry accessible interfaces, and install a known-good fully charged compatible FLEXVOLT pack until it
- - Press the lock-off deliberately and pull the trigger once with the blade clear of all material - if the worklight and motor both remain absent, keep the hou
This is a preview of the troubleshooting guidance included in the full repair manual.
Common Fixes
- Electronic module or brushless motor
- Worklight and lens
- FLEXVOLT battery pack
- Battery rails, contacts, latch, and release
- Trigger lock-off and trigger switch
- Electronic module, brushless motor, and electric brake
Related symptoms
The Saw Is Completely Dead - No Worklight And No Motor Response
A charged-looking battery is installed and the trigger is pulled, but the worklight never comes on and the blade does not move.