Search repair guides
Find repair guides, manuals, symptoms, and error codes across the knowledge base.
Battery repeatedly overheats or protection-stops during light use
Battery becomes unusually hot during an otherwise normal charge
Battery loses charge rapidly while stored disconnected
BATTERY SEATS BUT WILL NOT STAY LATCHED
BATTERY WILL NOT SLIDE FULLY INTO A COMPATIBLE TOOL OR CHARGER
Runtime is much shorter than a matched known-good battery
The battery latches normally and works while still, but charging or tool power stops, restarts, or flickers when the pack or receiver is gently moved.
The pack starts and runs a known-good compatible tool at no load, but output stops promptly during an ordinary matched task that a known-good battery completes.
The cool dry battery shell appears closed, but a new loose rattle, clunk or shifting movement is heard inside after a drop or impact, with no swelling, liquid, smoke, odor or heat.
A compatible charger continues to report its temperature-delay state after the battery has stabilized at room temperature and the charger works normally with another compatible battery.
The pack is fully seated, the release button is pressed, and the battery still cannot be slid out without excessive force.
The cool dry pack has a visibly cracked, missing, loose or distorted rail, release button, latch feature or molded support, whether or not insertion has been attempted.
With the pack removed and cool, one or more accessible power, signal or temperature contacts are visibly bent, pushed in, pitted, loose or corroded, with no active heat, smoke, liquid or melting.
A known-good compatible charger begins its normal charging cycle, but the cycle repeatedly stops, restarts, faults, or continues abnormally without reaching completion.
The battery reaches the normal seated position, but the release latch does not retain it and the pack can slide away without pressing the release button.
With the battery removed from every tool and charger, the charge-status button cannot be pressed normally, remains depressed or has broken away.
At room temperature in a proven compatible tool, the pack becomes unusually hot or repeatedly protection-stops during a light intermittent task that a known-good battery completes normally.
A proven compatible charger gives its normal full-charge indication, yet the removed battery shows little or no charge and can run a known-good low-load tool only briefly or not at all.
The pack is swollen, leaking or wet, smoking, sparking, melting, giving a strong burning or chemical odor, or dangerously hot during charging, use or storage.
At room temperature, the battery is fully seated in a powered known-good compatible charger, yet the charger never enters its normal charging state.
FM-05: CHARGE-STATUS INDICATOR GIVES NO RESPONSE
FM-03: A LATCHED BATTERY WILL NOT RELEASE FROM THE
FM-06: FM-06 CHARGE-STATUS SEGMENTS ARE STUCK, PARTIAL, OR
FM-04: Remove the battery from every device and inspect the button area without FM-04
fm-3-2: CHARGE-STATUS INDICATOR GIVES NO RESPONSE AFTER A CONFIRMED FULL CHARGE
FM-15: FM-15 BATTERY LOSES CHARGE RAPIDLY WHILE STORED DISCONNECTED
FM-16: FM-16 BATTERY REPEATEDLY OVERHEATS OR PROTECTION-STOPS DURING LIGHT USE
FM-17: FM-17 BATTERY BECOMES UNUSUALLY HOT DURING AN OTHERWISE NORMAL CHARGE
fm-1-1: A LATCHED BATTERY WILL NOT RELEASE FROM THE RECEIVER
FM-19: FM-19 RAIL, RELEASE BUTTON, LATCH, OR MOLDED FOOT IS VISIBLY BROKEN OR DISTORTED
FM-14: FM-14 RUNTIME IS MUCH SHORTER THAN A MATCHED KNOWN-GOOD BATTERY
FM-13: FM-13 BATTERY RUNS A TOOL AT NO LOAD BUT SHUTS DOWN UNDER ORDINARY LOAD
fm-3-4: BATTERY WILL NOT BEGIN CHARGING IN A KNOWN-GOOD COMPATIBLE CHARGER
fm-2-1: FM-01 BATTERY WILL NOT SLIDE FULLY INTO A COMPATIBLE TOOL OR CHARGER
fm-3-6: HOT OR COLD CHARGE DELAY PERSISTS AFTER THE BATTERY REACHES ROOM TEMPERATURE
fm-3-1: CHARGE-STATUS BUTTON IS JAMMED, BROKEN, OR WILL NOT RETURN
fm-5-1-2: FM-20 OUTER HOUSING IS CRACKED, SPLIT, PUNCTURED, OR OPEN AT A SEAM
fm-2-2: FM-02 BATTERY SEATS BUT WILL NOT STAY LATCHED
fm-3-3: CHARGE-STATUS SEGMENTS ARE STUCK, PARTIAL, OR IMPLAUSIBLE WHILE ENERGY OUTPUT IS NORMAL
FM-21: FM-21 A NEW INTERNAL RATTLE OR LOOSE MOVEMENT IS HEARD AFTER IMPACT
Known-good compatible charger
Herramienta compatible conocida y en buen estado
Bilinen iyi priz
Ventilated room-temperature area
Stable padded support
Known-good battery
Cool known-good Bosch 18V battery
Damaged-lithium recycling route
Cut-resistant gloves
Compatible Bosch 18V battery
An approved battery charger
Compatible charger
Correct impact bit
Half-inch impact socket
Hex adapter for short bits
Impact socket
A straight round-shank drill bit
Gloves
Driver bit or bit holder
Charger and indicator